How to refill gas wall-hung boiler
The gas wall-hung boiler is one of the important equipment for modern home heating. Regular maintenance and water replenishment are key steps to ensure its normal operation. This article will introduce in detail the water replenishment method, precautions and FAQs of the gas wall-mounted boiler to help users easily complete the operation.
1. Water replenishment steps for gas wall-hung boiler

Replenishing water is the basic operation for gas wall-hung boiler maintenance. The following are the specific steps:
| steps | Operating Instructions |
|---|---|
| 1. Check the pressure gauge | Make sure the wall-hung boiler is turned off and check the pressure gauge display (normal range is 1-1.5Bar). |
| 2. Find the water replenishment valve | The fill valve is usually a black or blue knob located at the bottom of the boiler. |
| 3. Open the water replenishment valve | Turn the water replenishing valve counterclockwise and stop when you hear the sound of water flowing. |
| 4. Observe the pressure gauge | When the pressure gauge pointer reaches 1.5Bar, close the water replenishment valve clockwise. |
| 5. Restart the wall-hung boiler | After replenishing the water, restart the boiler and check for normal operation. |
2. Precautions for hydration
During the water replenishment process, please pay attention to the following matters to avoid equipment damage caused by operating errors:
| Things to note | Description |
|---|---|
| 1. Frequency of hydration | Usually check the pressure every 1-2 months and replenish water if it is insufficient. |
| 2. Avoid overpressure | Pressure exceeding 2 Bar may cause the safety valve to leak water, requiring manual drainage and pressure reduction. |
| 3. Check for leaks | After replenishing water, check whether pipes and valves are leaking and deal with them in time. |
| 4. Antifreeze in winter | When not in use for a long time in winter, the water stored in the system needs to be drained to prevent frost cracking. |
3. Frequently Asked Questions
The following are common questions and answers that users frequently ask during the hydration process:
| question | Answer |
|---|---|
| 1. What should I do if the water replenishment valve cannot be opened? | It may be that the valve is corroded. Try tapping or dripping lubricant. Do not force it. |
| 2. Does the pressure continue to drop after rehydration? | There may be water leakage in the system. You need to check the pipes and radiators or contact after-sales service. |
| 3. Is it normal for the water flow to make a loud sound when replenishing water? | Normal, indicating that the water flow is filling the system, and the sound will disappear after the pressure stabilizes. |
| 4. How to solve the problem of "low voltage failure" when the wall-hung boiler prompts? | First replenish water according to the above steps. If the problem occurs repeatedly, check whether the expansion tank has failed. |
4. Recommended hydration tools
If you need auxiliary tools, you can refer to the following recommendations:
| Tool name | Purpose |
|---|---|
| 1. Pressure gauge detector | Accurately monitor system pressure changes. |
| 2. Leak-proof sealing tape | Wrap the threads of the refill valve to prevent water seepage. |
| 3. Portable drainage pump | Quickly drain the water stored in the system (for antifreeze in winter). |
5. Summary
Replenishing water in a gas wall-hung boiler is a simple but careful operation. Following the correct steps and precautions can effectively extend the life of the equipment. If you encounter a problem that cannot be solved, it is recommended to contact professional maintenance personnel in time. Regular maintenance can not only ensure the heating effect, but also avoid safety hazards.